- 美国DRIERITE目录-DRI...
- 美国Nationaldiagno...
- 美国Electron Micro...
-
美国电镜耗材总目录
-
脑矩阵
-
标样
-
碳/石墨棒
- 清洁用品
-
钻石刀
-
TEM支持膜
- 胶黏剂非导电 胶黏剂导电
-
烧杯
-
原子力显微镜用品
-
AFM探针
- 防静电产品
- 胶黏剂产品
-
铜网、镍网和金网
- Adhesives 胶粘剂 粘合...
-
Apertures 光圈孔径
-
Atomic Force Mic...
-
Beakers 烧杯
-
Brushes 生物刷
-
Calibration 校准产品
-
Carbon / Graphit...
-
Cleaning 清洁产品
-
Dissection Suppl...
-
Filaments / Cath...
-
Embedding Suppli...
-
Forensic 法医产品
-
FIB Supplies 纤维...
-
Grids 电镜网格系列
-
Materials Scienc...
-
Omniprobe Consum...
-
Scanning Electro...
-
Tweezers 镊子
-
Tools 工具
-
脑矩阵
-
KOVA公司产品
- 美国EIS
- 美国Tronex
-
APPLIED MICROARR...
- Drummondsci
- 美国PrimCells公司
- 美国Vector目录-Vecto...
-
美国VWR目录-VWR Cata...
-
General Catalogu...
- Adhesives-Autora...
- Bags-Barometers ...
- Baths-Blenders 水...
- Bottles 试验瓶
- Brushes-Casserol...
- Centrifuges-Chlo...
- Chromatography 层...
- Clamps-Cylinders...
- Data Loggers-Ele...
- Electrophoresis ...
- Electroporators-...
- Filters-Flashlig...
- Flasks-Furnaces ...
- Gas-Heating Tape...
- Hemacytometers-H...
- Humidity-Ice Mak...
- Incubators-Melti...
- Microbiology Med...
- Microscopes-Mill...
- Molecular Biolog...
- Ovens-Petroleum ...
- pH-Photometers 酸...
- Pipets-Pipettors...
- Plates-Rulers 酶标...
- Safety, Air Moni...
- Safety, Hearing ...
- Sample Cups-Spec...
- Spectrophotomete...
- Standards 标准液
- Stationery-Stopp...
- Surface Tension-...
- Thermometers-Tim...
- Tissue-Tubes,NMR...
- Tubing-Valves 导管...
- Vials-Watch Glas...
- Water Purificati...
-
Chemical Catalog...
- Acacia to Alumin...
- Amine-Sulfuric A...
- Balsam Canada So...
- Cacodylic Acid, ...
- Deblock Reagent ...
- Ecolite to Furfu...
- D-(+)-Galactose ...
- Imidazole to Lys...
- Magnesium to Myr...
- Naphthalene to 2...
- Palladium (II) A...
- Potassium Acetat...
- Saccharin Sodium...
- Sorbic Acid to S...
- TAE Buffer to Tr...
- Universal Indica...
-
Life Science Cat...
- Air-Antibodies 压...
- Apoptosis Reagen...
- Autoradiography-...
- Blotting-Bottles...
- Cell Cycle Reage...
- Centrifuges-Comb...
- Competent Cells ...
- Conductivity-Dia...
- DNA Synthesis Re...
- Electrophoresis-...
- Enzymes 酶
- Evaporators-Free...
- Fume Hoods-Histo...
- Homogenizers-Loo...
- Microscopes/Slid...
- Molecular Biolog...
- Nitric Oxide Rea...
- Peptide Synthesi...
- Petri-Photodocum...
- Pipetting 吸液管
- Plate Readers-Pl...
- Reagents, Specia...
- Refrigerators-Th...
- Tissue-Wipers 组织...
-
General Catalogu...
- 美国MatTek Corpora...
-
美国Nasco Whirl-Pa...
-
Whirl-Pak圆底采样袋
-
Whirl-pak耐高温采样袋
-
Whirl-Pak大肠菌群采样袋
-
Whirl-Pak均质袋
-
Whirl-Pak黑色采样袋
-
Whirl-Pak无菌采样袋(附...
-
Whirl-Pak可放置标牌的无...
-
Whirl-Pak防辐射采样袋
-
Whirl-Pak带泡沫采样袋
-
Whirl-Pak长期保存样品袋
-
Trans-Pak取样袋,带生物...
-
Whirl-Pak可标记宽钢丝封...
-
Whirl-Pak直立含硫代硫酸...
-
Whirl-Pak大容积采样袋
-
Whirl-Pak均质过滤袋
-
Whirl-Pak表面测试采样袋...
-
Whirl-Pak无菌水质采样袋
-
Whirl-Pak可直立圆底采样...
-
Whirl-Pak带标签无菌采样...
-
Whirl-Pak标准无菌采样袋
- Whirl-Pak®Bags 美...
-
Whirl-Pak圆底采样袋
- Berkshire
- 美国CORNING目录-CORN...
-
美国(Thermo Fisher...
-
**组化笔—PAP PEN
-
Thermo玻片-Thermo ...
- Fisher玻片-Fisher ...
- VWR玻片-VWR Slide
-
Corning玻片
-
NUNC玻片目录- NUNC C...
-
紫外光谱相关-UV spectr...
-
HAMILTON进样器-HAMI...
-
计时器-Timer
-
游标式瓶口分配器-Cursor-...
-
AMPULES安瓿瓶-Ampou...
-
袋子-Bags
-
称量用品-Weighing Pr...
-
烧杯-Beaker
-
实验台保护垫-Test bed ...
-
试剂瓶-Reagent bott...
-
滴定管-Buret
-
游标卡尺-Calipers
-
试剂桶-Reagent barr...
-
夹子和台架-Clip and S...
-
储样-Sample storag...
-
坩埚-Crucible
-
冻存-Cryopreservat...
-
量筒-Graduated cyl...
-
平皿-Plate
-
过滤产品-Filtration ...
-
烧瓶-Flask
-
容量瓶-Volumetric f...
-
地粘-stick
-
镊子-Forceps
-
漏斗-Funnel
-
玻璃割刀-Glass cutte...
-
手套-Gloves
-
组织学用具-Histology ...
-
冰盒-Ice box
-
标签带-Label with
-
微生物取样-Microbial ...
-
微量板-Micro plate
-
显微镜耗材-Microscope...
-
玛瑙研钵-Agate morta...
-
支架-Support
-
**用品-Safety Prod...
-
取样器-Sampler
-
剪刀-Scissors
-
标准筛-Standard sie...
-
抹刀-Spatula
-
磁力搅拌子-Magnetic s...
-
胶塞-Stopper
-
组织培养-Tissue Cult...
-
夹子-Clip
-
分配盘/托盘-Distribut...
-
管子-Tube
-
样品小瓶-Sample vial
-
利器存储桶-Tool bucke...
-
实验室用抹布-Laborator...
-
封口膜-Sealing film
-
移液管及**装置-Pipette...
-
移液枪-Pipette
-
**组化笔—PAP PEN
- 美国BD 公司产品
- 美国Nalgene 生物耗材
- **新品-New Product...
- VWR目录-VWR Catalo...
-
Corning目录-Cornin...
-
Millipore仪器耗材-Mi...
-
Merck试剂耗材-Merck ...
-
Whatman试剂耗材-What...
-
Axygen试剂耗材-Axyge...
- SAI-infusion
- ASI-instruments
-
PALL仪器耗材-Pall Ca...
- 细胞目录-Cell Lines
- 美国 Cell Marque
- Hamilton
- 菌株 菌种库 微生物菌种
-
NU-CHEK
- ATCC细胞 细胞株 肿瘤细胞
- 丹麦NUNC全目录
产品详情
简单介绍:
Troubleshooting Giude
详情介绍:
Troubleshooting Giude
Pipet-Aid Model: | Problem | Solution |
4-000-110 & 220 | No aspiration | 1. Check valve placed in upside down, black o-ring goes up into the handle. |
No aspiration | 1. Check valve in nosepiece needs to be cleaned out. Push wire or paperclip through black o-ring to open up check valve. When opened, rinse float and shell with water or alcohol. Allow to dry and reassemble. 2. Shake and listen for float to rattle. Reassemble into nosepiece and check for aspiration. 3. Tubing leading to vacuum side of pump has a hole in it. Cut out hole or replace tuging (4-000-004) 4. Hose connector missing or split. Replace hose connector (4-000-011) |
|
Pipet leaks after filling | 1. Replace rubber insert (4-000-002) 2. Check tubing for holes, replace or shorten if found. Hose connector missing or split. 3. Replace hose connector(4-000-011) 4. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). |
|
Fill/empty very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Clean out check valve or replace (4-000-003) 3. Buttons in valve body dirty, clean or replace. 4. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). |
|
4-000-110-TC & 220-TC |
No aspiration | 1. Check valve placed in upside down, black o-ring goes up into the handle. |
No aspiration | 1. Filter has been wetted. Replace with 4-000-051 2. TC gasket missing in nosepiece, requires one on each end of filter (4-000-057). 3. Tubing leading to vacuum side of pump has a hole in it. Cut out hole or replace tuging (4-000-004) |
|
Pipet leaks after filling | 1. Replace rubber insert (4-000-002) 2. Check tubing for holes, replace or shorten if found. 3. Hose connector missing or split. Replace hose connector (4-000-011). 4. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). |
|
Aspiration/fill very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Buttons in valve body dirty, clean or replace. 3. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). 4. Poor seal around filter; use Drummond filters (4-000-051). |
|
4-000-111 & 211 | No aspiration | 1. Check valve placed in upside down, black o-ring goes up into the handle. |
No aspiration | 1. Check valve in nosepiece needs to be cleaned out. Push wire or paperclip through black o-ring to open up check valve. When opened, rinse float and shell with water or alcohol. Allow to dry and reassemble. 2. Shake and listen for float to rattle. Reassemble into nosepiece and check for aspiration. 3. Tubing leading to vacuum side of pump has a hole in it. Cut out hole or replace tuging (4-000-004) 4. Hose connector missing or split. Replace hose connector (4-000-011) |
|
Pipet leaks after filling | 1. Replace rubber insert (4-000-002) 2. Check tubing for holes, replace or shorten if found 3. Hose connector missing or split. Replace hose connector (4-000-011) 4. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). |
|
Aspiration/fill very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Clean out check valve or replace (4-000-003) 3. Buttons in valve body dirty, clean or replace. 4. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). |
|
4-000-111-TC & 211-TC |
No aspiration | 1. Check valve placed in upside down, black o-ring goes up into the handle. |
No aspiration | 1. Filter has been wetted. Replace with 4-000-051 2. TC gasket missing in nosepiece, requires on on each end of filter (4-000-057). 3. Tubing leading to vacuum side of pump has a hole in it. Cut out hole or replace tuging (4-000-004) |
|
Pipet leaks after filling | 1. Replace rubber insert (4-000-002) 2. Check tubing for holes, replace or shorten if found. 3. Hose connector missing or split. Replace hose connector (4-000-011) 4. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). |
|
Aspiration/fill very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Buttons in valve body dirty, clean or replace. 3. Poor seal around filter; use Drummond filters (4-000-051) 4. Diaphragm inside pump is split or dried up and cracked, Replace diaphragms (4-000-010). 5. Poor seal around filter; use Drummond filters (4-000-051) |
|
4-000-100 & 200 | No aspiration | 1. Filter has been wetted. Replace with 4-000-051 2. TC gasket missing in nosepiece, requires on on each end of filter (4-000-057). |
No sound from motor when buttons depressed | 1. Battery needs to be charged overnight 2. Battery dead, replace with (4-000-035) 3. Listen for slight click when buttons are first pushed, if not heard, microswitch is broken, replace wire harness (4-000-046). |
|
Aspiration/fill very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Buttons in valve body dirty, clean or replace. |
|
Aspiration slow | 1. Poor seal around filter; use Drummond filters (4-000-051) 2. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) |
|
Unit leaks | 1. Replace rubber insert (4-000-002) 2. Poor seal around filter; use Drummond filters (4-000-051) 3. Check nosepiece for tight fit, if loose, replace (4-000-053-A) |
|
Buttons damaged | 1. Replace buttons (4-000-019) 2. Handle connector tubing has a pin hole in it, cut out if long enough or replace (4-000-013) |
|
Aspiration is very slow; dispensing may be slow or normal. | Probable Cause: Liquid has been aspirated into the pump, which causes the flapper valve to stick and not function properly. 1. Open up the handle by removing the nosepiece and the three screws holding the handle halves together. 2. Take out the pump by disconnecting it from the tubing and the electrical connector. 3. Unscrew the four screws that hold down the two dark sections of the pump. 4. Remove the upper section from the next lower section. The upper section has the two ports extending from it. Once removed, this will expose a semi-transparent rubber flapper valve. 5. Gently remove this piece, clean it and the chamber with water. Dry both pieces & then replace the flapper valve. 6. This flapper valve can only be installed one way. Use the locating pins to align the valve. There is one large pin and one small pin to prevent misalignment and improper orientation of the valve. 7. Reassemble and reinstall. Check for aspiration speed. To prevent this, the use of Drummond filters minimized the chance for damaging the valves but it may not always eliminate the problem. |
|
4-000-101 & 201 | No aspiration | 1. Filter has been wetted. Replace with 4-000-051 2. TC gasket missing in nosepiece, requires on on each end of filter (4-000-057). 3. "Fill" button between speed settings, Rotate to you feel it click into place. |
No sound from motor when buttons depressed | 1. Battery needs to be charged overnight 2. Battery dead, replace with (4-000-035) 3. Battery damaged by use of non-Drummond charger. Replace battery (4-000-035) |
|
Aspiration/fill very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Buttons in valve body dirty, clean or replace. |
|
Unit leaks | 1. Replace rubber insert (4-000-002) 2. Poor seal around filter; use Drummond filters (4-000-051) 3. Valve body o-rings need to be replaced. Call Drummond 1-800-523-7480 |
|
Aspiration is very slow; dispensing may be slow or normal. | Probable Cause: Liquid has been aspirated into the pump, which causes the flapper valve to stick and not function properly. 1. Open up the handle by removing the nosepiece and the three screws holding the handle halves together. 2. Take out the pump by disconnecting it from the tubing and the electrical connector. 3. Unscrew the four screws that hold down the two dark sections of the pump. 4. Remove the upper section from the next lower section. The upper section has the two ports extending from it. Once removed, this will expose a semi-transparent rubber flapper valve. 5. Gently remove this piece, clean it and the chamber with water. Dry both pieces & then replace the flapper valve. 6. This flapper valve can only be installed one way. Use the locating pins to align the valve. There is one large pin and one small pin to prevent misalignment and improper orientation of the valve. 7. Reassemble and reinstall. Check for aspiration speed. To prevent this, the use of Drummond filters minimized the chance for damaging the valves but it may not always eliminate the problem. |
|
4-000-105 | No aspiration | 1. Filter has been wetted. Replace with 4-000-051 2. TC gasket missing in nosepiece, requires on on each end of filter (4-000-057). 3. "Fill" button between speed settings, Rotate to you feel it click into place. |
No sound from motor when buttons depressed | 1. Plug in power supply/charger and use unit while it charges, use only power supply/charger 4-000-065. If battery will not hold a charger replace with new battery,(4-000-036) NOTE: Not the same battery as in the other portable units. |
|
Aspiration/fill very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Buttons in valve body dirty, clean or replace. |
|
Unit leaks | 1. Replace rubber insert (4-000-002) 2. Poor seal around filter; use Drummond filters (4-000-051 3. Valve body o-rings need to be replaced. Call Drummond 1-800-523-7480 |
|
4-000-300 & 302 & 303 | No aspiration | 1. Filter has been wetted. Replace with 4-000-051 2. TC gasket missing in nosepiece, requires on on each end of filter (4-000-057). 3. "Fill" button between speed settings, Rotate to you feel it click into place. |
Unit leaks | 1. Replace rubber insert (4-000-002) 2. Poor seal around filter; use Drummond filters (4-000-051) 3. Valve body o-rings need to be replaced. Call Drummond 1-800-523-7480 |
|
No sound when handle removed from cradle | 1. Actuator button is stuck in the down position. | |
Aspiration/fill very slow but no leaking | 1. Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002) 2. Buttons in valve body dirty, clean or replace. |
|
4-000-400 & 400-C | Unit will not turn "on" | 1. Hold menu button down until it flashes and turns on. 2. Unit not plugged into the power supply 3. On portable unit using batteries, the battery is not charged. |
Aliquot inaccurate | 1. Confirm you have the correct pipet settings (volume and brand) 2. Confirm you are using the correct filters, part number 4-000-051-E (essential for accuracy) |
|
Programmed aliquot is inaccurate | 1. Perform CAL. Scroll to OPTNS, press menu; cursor will be on CAL, press menu; scroll to YES, press menu; remove any pipets, press menu. | |
Programmed aliquot is inaccurate but consistant | 1. Scroll to OPTNS, press menu; scroll to OFST, press menu; scroll to YES, press menu; if aliquot is too small, lower OFST value and check/if aliquot is too large, increase OFST value and check. |